# Specification Writing & Code Compliance
Specifications translate design intent into construction instructions. AI accelerates the writing; your expertise ensures the accuracy.
Draft a specification section following CSI MasterFormat:
Section: 09 65 00 — Resilient Flooring
Project type: Medical office tenant improvement
Performance requirements:
- Commercial grade, healthcare-suitable
- Minimum 20-year warranty
- Anti-microbial surface treatment
- Chemical resistance (medical-grade cleaning agents)
- Slip resistance: minimum 0.6 wet DCOF
- Sound absorption: minimum IIC 50
Section structure:
PART 1 — GENERAL
1.01 Summary (scope, related sections)
1.02 References (ASTM standards, ADA, manufacturer requirements)
1.03 Submittals (product data, samples, test reports, warranty)
1.04 Quality Assurance (installer qualifications, mockup requirements)
1.05 Delivery, Storage, and Handling
1.06 Warranty
PART 2 — PRODUCTS
2.01 Manufacturers (approved list: 3 minimum, or equal clause)
2.02 Materials (LVT, sheet vinyl, rubber — specify performance criteria)
2.03 Accessories (adhesive, transition strips, base, welding rod)Upgrade to Pro to access the full content